Fuji Electric FCX-AII V5 Differential Pressure Transmitters
| The Fuji Electric FCX-AII V5 series of differential pressure transmitters use
a silicon micro-capacitance cell proven on thousands of difficult
applications. Fuji Electric transmitters are installed in harsh environments on oil
pipelines, power stations, gas compressor stations, water treatment
plants and steel plants. They have European, American, Russian and
Chinese approvals. Field repair is possible using only one amplifier
for all pressure transmitter types. |  |

| Highlights |
Application flexibilityDifferential pressure transmitters can be used to measure, flow, density, viscosity and level.
Flow measurement, DP
transmitters measure the pressure drop accross orifice plates, venturi
tubes, pitot tubes or some other form of primary flow element. In these
applications there is a square law relationship between the
differential pressure and the flowrate. When specifying a dP
transmitter for a flow applications the type of fluid, line pressure
and temperature as well as flow trundown should be known.
Fuji Electric have recently released the worlds first
DP transmitter which will measure differential pressure at line
pressures up to 1035 barg!. This "high static pressure" device is
particulary useful in the oil and gas industry as producers drill to
new depths to recover product.
Density Measurement, DP
transmitters measure the difference in pressure between two points in a
vertical plane. The density being proportional to the difference in
pressure.
Viscosity Measurement, in this
application a fixed flowrate is pumped through an orifice plate at a
constant rate using a positive displacement pump at a known telperature
and pressure. By measuring the differential pressure accross the
orifice plate, the viscosity of the fluid can be measured.
Level Measurement, in this
application the level in a sealed tank can be measured by comparing the
pressure at the top of the tank, with the pressure at (or near) the
bottom of the tank. fuji Electric DP transmitters have the capability
to compensate for tanks with irregular shapes.
Applications in HVAC,
water treatment, food, paper, pharmaceutical, chemical, petrochemical,
offshore, sub-sea and nuclear industries can be satisfied by this range
of transmitters.
By selecting from a large range of materials, we are able to customise
the transmitter and supply remote seals. We temperature compensate the whole
assembly to maintain the highest level of performance. Selecting from
316SS, Hastelloy, Monel, Tantalum, Gold and Ceramic we can custom build
a transmitter to our own high standards, or to your individual specifications.High Static DP transmitters,
The FCX-AII V5 transmitter is the only DP transmitter of its type with a design static pressure of 1035Bar. Oil
& Gas producers are drilling to new depths to keep up with demand,
but this creates problems for traditional differential pressure
transmitters, that are not designed to operate above 6000PSI (414 barg).
Based
on extensive experience of supplying transmitters for this demanding
application, Fuji Electric is proud to announce the release of its
latest Differential Pressure Transmitter which has is specifically
designed to solve customer's requirements in high pressure applications. Each transmitter design is application specific. To
provide high flexibility, Remote Seals can be fitted to any of the FCX
series of transmitters.
Wetted parts in SS 316L, Hast C 276, Duplex, Monel, Tantalum, or
others on request
| 
|
Please note that there is no datasheet available for high static transmitters. These transmitters are custom built on an application by application basis.
For transmitters to suit any of the above applications, please do not hesitate to contact us.
Common Specifications
| Diaphragm materials
| SS316L, hastelloy-C, monel, tantalum, zirconium, titanium, double coated with gold and ceramic
| Elevation/suppression
| -100 to +100%URL
| Span measuring range
| 100 to 1/100 URL
| Liquid contacting temperature
| -40 to 120ºC
| Ambient temperature
| -40 to 85ºC
| Output signal / Allowable load resistance
| DC 4 to 20mA / 600 Ohm
| Supply voltage
| DC 10.5 to 45V
| Long-term stability
| ±0.1% URL/10 years
| Explosion-proof specification
| Flameproof, intrinsic safety type
| Mounting method
| 50A pipe mounting, direct mounting
| Weight
| 2.9Kg (standard unit)
|
Differential Pressure (flow) transmitter
| Type
| FKC (or FKD with remote seal)
| Measuring span
| 1/6/32/130/500/3000/20000 kPa
| Maximum static pressure
| 2/10/16/30/42 MPa
| Measuring accuracy
| Up to ±0.04% Standard: ±0.065%
|
Download Listing |
One Download |
|
Download Listing |
2 Downloads |
|
|